Product Details:
|
Place Of Origin: | China | Brand Name: | Rainbow |
---|---|---|---|
Model Number: | ECG-8203 | Power Source: | Electric |
Warranty: | 1 Year | After-sale Service: | Online Technical Support |
Material: | Plastic | Quality Certification: | Ce |
Instrument Classification: | Class II | Type: | Medical Device ECG |
Display: | 7 Inch Colar LCD Touch Screen | Sale Points: | Support SD Card, USB Disk |
Lead: | 12 Leads | ||
Highlight: | 12 Leads Ecg Machine,3 Channel EKG Device,Hospital Touch Screen Ecg Machine |
Features
1.Digital signal processor for effective inhibition of baseline drift, AC interference filter, MG interference filter and the heart rate, to guarantee the authenticity and dependability
2.Auto-regulation of baseline drift can effectively inhibit baseline drift, optimizing the printing position to achieve high-quality ECG
3.Have regular automatically measuring and analyzing function for ECG parameters to lessen doctor's load.
4.With a high -resolution thermal printer to print out ECG trace, describing the trace clear and accurate, annotation as well as related parameters for diagnostic reference.
5.Roll recording paper for ECG is 80mm in width, simultaneous 12 lead acquisitions and 3 lead live record, high affectivity of ECG examination, good effect and economic utility.
6.Function of rhythm lead for observing abnormal ECG trace & heart rate.
7.Supported by AC/Rechargeable battery for continuous examination whenever necessary. For Battery operation.
8.ECG is equipped with a battery charger and a system for battery capacity management and protection
Safety level for ECG corresponds to Type CF, Class I according to the IC60601-1 criterion. The amplifier is floating input circuit which can examine human cordis directly with safety and reliability
Main technical specification
Items | specification |
Lead | standard 12 leads |
lead acquisition | synchronously 12 leads |
Input circuit | Floating; Protection circuit against Defibrillator effect |
Input Impedance | ≥50MΩ |
Input circuit current | ≤0.0.05 A |
Record mode | Automatic: 3CH×4+1R, 3CH×4, 3СН×2+2CH×3,3CH×2+2CH×3+1R,6CHX2; Manual: 3CH, 2CH, 3CH+1R, 2CH+1R; Rhythm: Any lead selectable. |
Filter | EMG Filter: 25 Hz / 30 Hz/ 40H2/75 Hz/ 100 Hz / 150Hz DFT Filter: 0.05 Hz/ 0.15 Hz AC Filter: 50 Hz/ 60Hz |
CMRR | >100dB |
Patient current leakage | <10 A |
Input Circuit Current | <0.05 A |
Frequency Response | 0.05Hz~150Hz (-3dB) |
Sensitivity | 2.5mm/m V, 5 mm/m V, 10 mm/m V, 20 mm/mV |
Anti-baseline Drift | Automatic |
Time constant | ≥3.2s |
Noise level | <15 Vpp |
Paper speed | 12.5 mm/s, 25 mm/s, 50 mm/s |
Recording mode | Thermal printing system |
Paper specification | 80mmx20m paper roll |
LCD display | 7''graphic LCD |
Safety classification | IEC60601-1 class I, type CF |
Power supply | AC: 100~240V, 50/60Hz, 30VA~100VA |
DC: 14.8V/2200mAh, built-in lithium battery | |
Fuse | AC220V=10% 2*Ф5×20mm, T2A/250V AC time lag |
AC110V+10% 2*Ф5×20mm.T4A/250V AC time lag |
Accessories
Item | Description | Quantity |
1 | Patient Cable | 1 |
2 | Limb Electrode | 4pcs/set |
3 | Chest Electrode | 6pcs/set |
4 | Three plugged power cable | 1 |
5 | Grounding Cable | 1 |
6 | Paper Shaft | 1 |
7 | Thermal Recording Paper | 1 |
Contact Person: Lily