Product Details:
|
Place Of Origin: | China | Brand Name: | Rainbow |
---|---|---|---|
Model Number: | RBH-800 | Warranty: | 1 Year |
After-sale Service: | Online Technical Support | Product Name: | Syringe Pump |
MOQ: | 1 Set | Infusion Mode: | Speed Infusion,speed Time Infusion,speed Volume Infusion |
Display: | 4.3 Inch LCD | Battery Working Time: | No Less Than 8 Hour |
KVO Speed Range: | 2.5ml/h | Dimension: | 248*151.5*97mm |
Highlight: | 4.3In Single Channel Syringe Pump,Medical Single Channel Syringe Pump,RBH-800 Medical Syringe Pump |
Product Description
This product doesnot provide an infusion set,
It has a safety design that avoids misoperation during infusion and doesnot cut off the power immediately after pressing the power button.
It has a safe design to prevent air bubbles in the infusion from entering the patient's blood vessel.
The device can use two types of power sources: AC power and built-in battery power.
①:Alarm indicator
②:Start/stop injection button
③:Mute button
④:Quick button
⑤:Power button
⑥:Syringe pump pushrod
⑦:Display screen
Features
Alarm information and processing method
Alarm items and alarm display | reasons | Treatment suggestion |
The liquid will be exhaused | Preset amount or set time remaining 5% | After the infusion solution is used up, if you want to continue the infusion, you should replace the infusion bottle or infusion bag; if the infusion solution is not used up, check whether the installation position of the drip rate sensor is correct or whether it is abnormally inclined. |
Infusion completed | The infusion has reached the set time or volume value | Press the mute button to eliminate the prompt |
Blocked tubing | The infusion push rod is blocked and the pressure reaches the alarm value | Check if there is any interference in the push rod, reinstall the syringe without interference or increase the blocking pressure level. If the blocking alarm occurs again, immediately stop using the system and contact the distributor/manufacture where you purchased the product. |
Battery is low | When the battery power is 20% remaining | Check whether the power supply used is properly connected to the system.(this alarm can be cleared by long pressing the mute button. and this alarm will not be reported in the future;or access to the AC to clear the alarm and the subsequent AC power faliure will continue to alarm) |
Dead battery | When the battery power is less than 5% | Immediately connect to AC power and the alarm is eliminated.(you cannot slience the alarm sound by pressing the "mute button") |
Syringe not installed | During the infusion, the syringe was not detected | Check whether the currently set syringe manufacturer selection is the manufacturer required by 6.5.4,If you have redefined the syringe type yourself, please switch to the set syringe manufaturer number. |
Contact Person: Lily