Product Details:
|
Type: | Medical Syringe Pump | Weight: | 2.2kg |
---|---|---|---|
Name: | Syringe Pump | Original: | Hunan,China |
Highlight: | Multiple Mode Medical Syringe Pump,2.2kg Medical Syringe Pump,OEM Syringe Pump |
Product description |
1.The pressure detection sensor with its own patented technology is adopted, and the injection pressure detection is more accurate, which greatly reduces the false alarm or non-alarm . |
2.A unique circuit safety design is used to ensure safe infusion. |
3.The high-resolution motor drive chip is used to make the injection more uniform and the water pulsation is small, especially at low flow rate, which obviously improves the common defects of large water pulsation in ordinary injection pumps. |
4.It adopts full Chinese large screen display and digital key menu operation, which is intuitive and convenient. |
5.It has the function of historical operation record, and automatically records the parameters and stop reasons of each injection operation, which is convenient for users to query and provide basis for reducing doctor and patient relationship disputes. |
Main features | Reliable and Safe: Advanced safety design able to stop infusion and alarm even if the CPU damage,the medical staff can ues it safely. |
Applicable syringe | 5ml,10ml,20ml,30ml,50/60ml |
The maximum flow rate range | 5ml syringe: 0.1ml/h~200ml/h |
10ml syringe: 1ml/h~300ml/h | |
20ml syringe: 1ml/h~400ml/h | |
30ml syringe: 1ml/h~600ml/h | |
50/60ml syringe: 1ml/h~1200ml/h | |
Precision | Better than ±2%; (but 5ml syringe and <1ml/h: Better than ±8%) |
Parameter range | 1, Flow-rate: 0.1~1200.0 ml/h, 0.1ml/h step; 2, Dose: 0.1~999.9 mg, 0.1mg step; 3, mg/kg/h: 0.001~999.999 mg/kg/h, 0.001 mg/kg/h step; 4, Body-weight: 1~300 kg, 1kg step; 5, KVO rate: 0.1~5.0 ml/h, 0.1 ml/h step; 6, Bolus rate: 0.1~1200.0 ml/h, 0.1 ml/h step; 7, Bolus volume: 0.1~99.9 ml/h, 0.1ml step |
Alarm | 1, Occlusion,0~175KPa, 8 grades of sensitivity; 2, Pressure sensor is abnormal; 3, Push rod fall off; 4, The drug running out; 5, The injection will finish; 6, The motor rotation fault; 7, Overtime pause; 8, Low battery; 9, Battery failure; 10, Battery temperature is too high; 11, Mains missing tips; 12, MCU fault, and stop injection. |
Data function | 1, Memory of parameter: Records the latest injection parameter for next operation; 2, Historical records: records latest 1000 injection events. (what/when/why,flow-rate, etc.) |
Packing
Package Size: 37*16*21
Net Weight: 1.65kg
Gross Weight: 2.2kg
Shipping:
Air shipping or Express courier is recommended if the order quantity was less than 20 units. It usually takes around 7 days to reach the destination. By ocean shipping, it normally takes 20-40 days depending on the destination port.
Safety classification | Class I; Internal power supply, CF type, IPX4 equipment |
Power supply | AC 100~240V, 50/60Hz, Built-in rechargeable Li-battery |
Power consumption:20VA | |
Working time of battery: 10h@5ml/h | |
Weight and size | 37cm(w)*24cm(h)*21cm(t); about 2.1kg |
Optional accessories | Wireless communicating module. |
Chinese Certificate | yes |
Contact Person: Lily