Product Details:
|
Product Name: | Patient Monitor | Brand Name: | RAINBOW |
---|---|---|---|
Highlight: | 12.1'' Multi Parameter Patient Monitor,220V Multi Parameter Patient Monitor |
Basic information:
6 parameters | ECG,HR/PR,SPO2,NIBP,RESP, TEMP |
Size | 12.1 inch portable ICU monitor |
Weight | 3.1kg(with lithium battery) |
Voltage | 220v |
Power | 40w |
Leads | 3-5 leads |
Suitable places | Bedside care ward, ICU, CCU, operating theaters, emergency centers, family care and the like. |
Optional | ETCO2 module; Build-in thermal printer; lithium battery; mobile stand/ wall mount |
SFDA classification | Class II |
Working system | Continuous running equipment |
Features: |
12" color TFT display, up to 12 waveforms Arrhythmia analysis, ST calculation, Pace analysisnew |
high-precision modules, new digital oxygen technology |
Patient info input management function |
Various interfaces: A single guide, standard, large font, all leads Anti-ESU, anti- defibrillator |
Multi-lead ECG waveforms display in phase |
Standard configuration: |
PM-9000GTA patient multi parameter monitor×1 set, |
Rechargeable lithium battery×1 pcs, |
standard 5-leads ECG conductance joint connecting cables×1 set, |
standard adult blood pressure cuffs×1 set, |
adult SPO2 probe×1 set, |
TEMP probe×1 set, |
power plug line×1 set, |
grounding wire×1 set, |
English operation manual×1 set. |
Three certificates×1 set. |
Optional:
EtCO2 module; Build-in rechargeable lithium battery; build-in thermal printer; monitor mobile stand/ wall mount
Technical parameters
ECG |
lead mode;I,II,III,AVR,AVL,AVF,V1-6 Gain: ×0.25, × 0. 5, and × 1, × 2 Frequency: 0.5 Hz - 100 Hz Common-mode signal inhibition: More than 70 dB Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls. HR: ± 5 BPM Precision calibration signal: 1mv(peak, ± 3% accuracy) ST Detection: measurement range (-2.0mV----+2.0mV) Using Standard: meet the ANSI / AMI EC13 -2002 standard Response time: 1s Alarm: Sound and Light Preset heart rate range: (Alarm over preset numerical) Ceiling: 1-255 bpm adjustable Threshold: 0-254 bpm adjustable |
NIBP |
Technology: Oscillography Mode: manual / automatic Measurement units: mmHg / kPa Scope: Pressure Cuffs 0-250 mmHg Inflatable cuffs: 180 mmHg (120mmHg for children, 70mmHg for newborn) Inflatable cuffs follow: original SBP: + 30 mmHg Measuring range: SYS: 60-250 mmHg DIA: 40-220 mmHg MEAN: 45-235 mmHg Response time: 1s Alarm: Sound and Light Preset range: report (Numerical exceed preset alarm) SYS: maximum: 1-255 mmHg adjustable Threshold: 0-254 mmHg adjustable DIA: ceiling: 1 -255 mmHg adjustable Minimum standards: 0-254mmHg adjustable |
SPO2 |
Range: 0-100% Accuracy: 1% Resolution: 1% Pulse frequency: 20-250 times / min Response time: 1s Alarm: Sound and Light Preset range: (report Alarm over preset numerical) Ceiling: 1% - 100% adjustable Threshold: 0% - 99% adjustable |
TEMP |
Technology: thermostat temperature probe Measuring range: 20 ° C-45 ° C Temperature resolution: 0.1% Accuracy: ± 0.1 ° C Response Time: 1s Alarm: Sound and Light Preset range: report (numerical preset alarm over) Maximum: 20.1 ° C-45.5 ° C adjustable Threshold: 20 ° C-45.4 ° C Adjustable |
RESP |
Breathing frequency range: 0-60 bum Accuracy: ± 1rpm Response time: 1s Gains options: × 1, × 2, × 0.5, and × 0.25 four trenches Alarm: Sound and Light Alarm range: (numerical preset alarm over) Ceiling: 10-100 bpm adjustable Threshold: 0 -99 bpm adjustable |
Printer(Optional)
|
Specification: Dual channel thermal array data recorder Print mode: Real time or event triggered record waveform and text Accuracy: horizontal: 4oodpi vertical: 800dpi Annotation: Date/ time(24 hours) Optional wall bracket, mobile stand, visits backpack. |
System |
Screen:12.1 inches TFT screen of LCD Battery: sealed maintenance-free lithium battery Safety standard: lec601-1(GB9706.1) |
Contact Person: Lily