Product Details:
|
Type: | Patient Monitor | Instrument Classification: | Class II |
---|---|---|---|
Product Name: | Patient Monitor | Warranty: | 2 Years |
Application: | ICU,Adult,ECG, Hospital, Bedside, Clinics | Display: | Color TFT LCD Touch Screen Display |
Size: | 12.1 Inch | Functions:: | ECG, Heart Rate, Oxygen Saturation, NIBP,TEMP,RESP |
Packaging: | Anti-collision Film+ Carton Box Carton Box Dimension: 40*30*35cm Gross Weight: 5.47kg | ||
Highlight: | ECG 6 Parameter Patient Monitor,NIBP 6 Parameter Patient Monitor,ICU Cardiac Monitor 12.1 Inch |
Brand Name: | Rainbow |
Size: | 12.1 inch |
Model: | PM-9000A |
Functions: | ECG, Heart rate, oxygen saturation, NIBP,TEMP,RESP |
Manufacturer: | Hunan Rainbow Technology, Ltd. |
Features:
1. Brand-new model design, combines Chinese classical elegance and European style. |
Standard configuration:PM-9000A multi parameter patient monitor×1 set, standard 5-leads ECG conductance joint connecting cables×1 set, standard adult blood pressure cuffs×1 set, adult SPO2 probe×1 set, TEMP probe×1 set, power plug line×1 set, grounding wire×1 set, English operation manual×1 set, three certificates×1 set.
Optional::three-channel thermal printer, monitor cart / support bracket/rack
Children/newborn SPO2 probe,Children/newborn blood pressure cuffs
Technical parameters:
Lead mode;I,II,III,AVR,AVL,AVF,V1-6
Gain: ×0.25, × 0. 5, and × 1, × 2
Frequency: 0.5 Hz - 100 Hz
Common-mode signal inhibition: More than 70 dB
Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls.
HR: ± 5 BPM
Precision calibration signal: 1mv(peak, ± 3% accuracy)
ST Detection: measurement range (-2.0mV----+2.0mV)
Using Standard: meet the ANSI / AMI EC13 -2002 standard
Response time: 1s
Alarm: Sound and Light
Preset heart rate range: (Alarm over preset numerical)
Ceiling: 1-255 bpm adjustable
Threshold: 0-254 bpm adjustable
Technology: Oscillography
Measurement method:more accurate with reverse measurement
Measurement units:mmHg/Kpa
Overvoltage protection:double safety protection
Measure time:less than 45S
Scope: Pressure Cuffs 0-250 mmHg
Measure accuracy:ANSI/AAMI SP10-2002 standard average accuracy and deviation
Inflatable cuffs: 180 mmHg (120mmHg for children
Inflatable cuffs follow: original SBP: + 30 mmHg
Measuring range:
SBP 60 mmHg~250 mmHg
Pmean 45 mmHg~235 mmHg
DBP 40 mmHg~220 mmHg
Measure accuracy:±1.1KPa(±8mmHg)±10%
Response time: 1s
Alarm: Sound and Light
Preset range: report (Numerical exceed preset alarm)
SBP maximum 1mmHg~255 mmHg
Threshold 0 mmHg~254 mmHg
DBP maximum 1mmHg~255 mmHg
Threshold 0 mmHg~254 mmHg
Alarm accuracy:±1 mmHg
Standard: ANSI/AAMI SP10-2002
Range: 0-100%
Accuracy: 1%
Resolution: 1%
Pulse frequency: 20-250 times / min
Response time: 1s
Alarm: Sound and Light
Preset range: (report Alarm over preset numerical)
Ceiling: 1% - 100% adjustable
Threshold: 0% - 99% adjustable
Technology: thermostat temperature probe
Measuring range: 20 ° C-45 ° C
Temperature resolution: 0.1%
Accuracy: ± 1 ° C
Response time: 1s
Alarm: Sound and Light
Preset range: report (numerical preset alarm over)
Maximum: 20.1 ° C-45.5 ° C adjustable
Threshold: 20 ° C-45.4 ° C Adjustable
Alarm accuracy:±1℃
Breathing frequency range: 0-60 bum
Accuracy: ± 1rpm
Response time: 1s
Gains options: × 1, × 2, × 0.5, and × 0.25 four trenches
Alarm: Sound and Light
Ceiling: 10-100 bpm adjustable
Threshold: 0 -99 bpm adjustable
Alarm accuracy:±1rpm
Specification:three-channel thermal recorder
Screen:12.1 inches TFT screen of LCD
Battery: sealed maintenance-free lithium battery
Safety standard: lec601-1(GB9706.1)
Contact Person: Lily