ISO13485 Portable Patient Monitor 7 Inch Colorful Disaplay Built In Rechargeable Battery

ISO13485 Portable Patient Monitor 7 Inch Colorful Disaplay Built In Rechargeable Battery
ISO13485 Portable Patient Monitor 7 Inch Colorful Disaplay Built In Rechargeable Battery ISO13485 Portable Patient Monitor 7 Inch Colorful Disaplay Built In Rechargeable Battery

Large Image :  ISO13485 Portable Patient Monitor 7 Inch Colorful Disaplay Built In Rechargeable Battery

Product Details:
Place of Origin: Hunan, China
Brand Name: RAINBOW
Certification: ISO13485, FSC
Model Number: PM-9000 7 inch
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Packing terms: Anti-collision film+ Carton box Carton box dimension: 40*30*35cm Gross weight: 4.4 kg
Delivery Time: Within 3 days
Payment Terms: Western Union, T/T, Western Union, MoneyGram
Supply Ability: 30000units/year

ISO13485 Portable Patient Monitor 7 Inch Colorful Disaplay Built In Rechargeable Battery

Description
Size: 7 Inch Optional: Rechargeable Lithium Battery; Build-in Thermal Printer; Monitor Mobile Stand/ Cart
Weight: 1.5KG Application Range: Widely Used In Hospital Departments Bedside Care Ward, ICU, CCU, Operating Theaters, Emergency Centers, Family Care And The Like.
Inventory: Yes ECG Leads Choices: All, I, II, III, AVF, AVR, AVL. V1--6 Chest Leads Showed
Highlight:

Rechargeable Battery Portable Patient Monitor

,

ISO13485 Portable Patient Monitor

Built-in rechargeable battery Portable Patient Monitor 7-inch colorful disaplay

 

Features:

1.With a new high-precision modules, new digital oxygen technology, measurement is more comprehensive and accurate.
2.High brightness resolution 7 inches color TFT LCD display, compact design, weighing only 1.5KG.
3. ST segment automatic detection, arrhythmia analysis, drug concentrations drop table analysis.
4.Throughout the whole parameter trend chart data, ECG waveform storage playback, power-down save function.
5.Jog shuttle operation, in English logo button, easy to use, simple and intuitive operation.
6.A single guide, standard, large font, all leads, trend charts coexist to meet more clinical needs.
7. Optional built-in rechargeable lithium battery, AC-DC dual-use, light weight, energy-saving and environmental protection.
8. Widely used in hospital departments bedside care ward, ICU, CCU, operating theaters, emergency centers, family care and the like.
9. Optional wall bracket, mobile stand, visits backpack.

 

Standard configuration:

PM-9000 7 inch transport monitor×1 set,

built-in rechargeable lithium battery×1 set,

build-in thermal printer×1 set ,

standard 5-leads ECG conductance joint connecting cables×1 set,

standard adult blood pressure cuffs×1 set,

adult SPO2 probe×1 set,

TEMP probe×1 set,

power plug line×1 set,

grounding wire×1 set,

English operation manual×1 set.

three certificates×1 set.

 

Optional: rechargeable lithium battery; build-in thermal printer; monitor mobile stand/ cart.

 

 

Technical parameters

 

ECG measurement:

Leads choices: All, I, II, III, aVF, aVR, aVL. V1--6 chest leads showed

Gains options: × 1, × 2, × 0. 5, and ×4 four trenches

Frequency: 0.5 Hz - 100 Hz

Common-mode signal inhibition: More than 70 dB

Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls.

HR: ± 5 bpm

Precision calibration signal: 1mv(peak, ± 3% accuracy)

ST Detection: measurement range (-1.0mV----+1.0mV)

Using Standard: meet the ANSI / AMI EC13 -2002 standard

Response time: 1s

Alarm: Sound and Light

Preset heart rate range: (Alarm over preset numerical)

Ceiling: 1-255 bpm adjustable

Threshold: 0-254 bpm adjustable

 

NIBP measurement

Technology: Oscillography

Mode: manual / automatic

Measurement units: mmHg / kPa

Protection: Double security protection

A measurement time: less than 45 S

Scope: Pressure Cuffs 0-250 mmHg

Blood pressure measurement accuracy: ANSI /AAMI, SP10-2002 standard error and standard deviation of the average value of the initial

Inflatable cuffs: 180 mmHg (120mmHg for children, 70mmHg for newborn)

Inflatable cuffs follow: original SBP: + 30 mmHg

Blood pressure measuring range:

Systolic blood pressure: 60-250 mmHg

Diastolic blood pressure: 40-220 mmHg

Pressure on the average: 45-235 mmHg

Response time: 1s

Alarm: Sound and Light

Preset range: report (Numerical exceed preset alarm)

Systolic blood pressure maximum: 1-255 mmHg adjustable

Threshold: 0-254 mmHg adjustable

Diastolic blood pressure ceiling: 1 -255 mmHg adjustable

Minimum standards: 0-254 mmHg adjustable

Use standard: compliance with the ANSI / AAMI SP10-2002 standard

 

Spo2 measurement

Range: 0-100%

Accuracy: 1%

Resolution: 1%

Pulse frequency: 20-250 times / min

Response time: 1s

Alarm: Sound and Light

Preset range: (report Alarm over preset numerical)

Ceiling: 1% - 100% adjustable

Threshold: 0% - 99% adjustable

 

TEMP measurement:

Technology: thermostat temperature probe

Measuring range: 20 ° C-45 ° C

Temperature resolution: 0.1%

Accuracy: ± 0.1 ° C

Response Time: 1s

Alarm: Sound and Light

Preset range: report (numerical preset alarm over)

Maximum: 20.1 ° C-45.5 ° C adjustable

Threshold: 20 ° C-45.4 ° C Adjustable

 

RESP Breath

Breathing frequency range: 0-60 bum

Accuracy: ± 1rpm

Response time: 1s

Gains options: × 1, × 2, × 4, and × 0.5 four trenches

Alarm: Sound and Light

Alarm range: (numerical preset alarm over)

Ceiling: 10-100 bpm adjustable

Threshold: 0 -99 bpm adjustable

 

Printer(Optional)

Specification: Dual channel thermal array data recorder

Print mode: Real time or event triggered record waveform and text

Accuracy: horizontal: 4oodpi vertical: 800dpi

Annotation: Date/ time(24 hours)

Optional wall bracket, mobile stand, visits backpack.

 

System

Screen:7/8 inches TFT screen of LCD

Battery: sealed maintenance-free lithium battery

Safety standard: lec601-1(GB9706.1)

 

ISO13485 Portable Patient Monitor 7 Inch Colorful Disaplay Built In Rechargeable Battery 0

ISO13485 Portable Patient Monitor 7 Inch Colorful Disaplay Built In Rechargeable Battery 1

ISO13485 Portable Patient Monitor 7 Inch Colorful Disaplay Built In Rechargeable Battery 2

ISO13485 Portable Patient Monitor 7 Inch Colorful Disaplay Built In Rechargeable Battery 3

ISO13485 Portable Patient Monitor 7 Inch Colorful Disaplay Built In Rechargeable Battery 4

ISO13485 Portable Patient Monitor 7 Inch Colorful Disaplay Built In Rechargeable Battery 5

ISO13485 Portable Patient Monitor 7 Inch Colorful Disaplay Built In Rechargeable Battery 6

ISO13485 Portable Patient Monitor 7 Inch Colorful Disaplay Built In Rechargeable Battery 7

ISO13485 Portable Patient Monitor 7 Inch Colorful Disaplay Built In Rechargeable Battery 8

Packing

Packing terms: Anti-collision film+ Carton box

Carton box dimension: 40*30*35cm

Gross weight: 4.4 kg

Shipping:

Air shipping or Express courier is recommended if the order quantity was less than 20 units. It usually takes around 7 days to reach the destination. By ocean shipping, it normally takes 20-40 days depending on the destination port.

ISO13485 Portable Patient Monitor 7 Inch Colorful Disaplay Built In Rechargeable Battery 9

ISO13485 Portable Patient Monitor 7 Inch Colorful Disaplay Built In Rechargeable Battery 10

 

What is your MOQ?

1 unit

What is your lead time?

Within 3 days after receiving the payment

What is the payment terms?

TT(Bank Transfer), Paypal, Western Union, Moneygram, XTransfer.

What is the warranty period?

2 years warranty period

Lifetime online technical support

Do you offer OEM service?

Yes, we do

 

 