Product Details:
|
Pumping Way: | Semi-squeeze Finger-type Peristaltic Pump | IV-sets: | Special Or Quality PVC/TPE Infusion Sets With An External Diameter Of 3.4mm~4.5mm |
---|---|---|---|
Precision: | Better Than ±5% (using A Calibrated Or A Special IV-set) | Optional Accessories: | 1, Warmer; 2, Wireless Communicating Module. |
Inventory: | Yes | OEM: | Chinese Certificate |
Highlight: | Continuous Enteral Feeding Pump,Electric Enteral Feeding Pump,Enteral Continuous Feeding Pump |
Main features | Reliable and Safe: 1, Additional set of bubble alarm design(double bubble alarm) ensure more secure infusion; 2, Advanced safety design able to stop infusion and alarm even if the CPU damage,the medical staff can ues it safely; multipurpose: Continuous feeding mode, Intermittent feeding mode. Reduce the treatment costs: Using common IV-set, No specific nutrient tube is required. |
Pumping way | Semi-squeeze finger-type peristaltic pump |
IV-sets | Special or quality PVC/TPE infusion sets with an external diameter of 3.4mm~4.5mm |
Feeding modes | 4 Feeding modes: 1, Flow-rate: ml/h; 2, Time-amount: ml/h; 3, Drop-rate: d/min; 4, Intermittent feeding mode. |
Parameter range | 1, Flow-rate: 1.0~1200.0 ml/h, 0.1ml/h step; 2, Time: 1s~99h59m59s, 1s step; 3, Drop-rate: 1~333 d/min, 1 d/min step. |
Precision | Better than ±5% (using a calibrated or a special IV-set) |
Alarm | 1, Air in tube, 5 grades of sensitivity; 2, Bubble sensor fault; 3.1, Upper-end occlusion, -20~ -60 kPa,8 grades of sensitivity; 3.2, Upper-end base-pressure fault; 4.1, Lower-end occlusion, 20~ 140 kPa,8 grades of sensitivity; 4.2, Lower-end base-pressure fault; 5.1, Pump rotation fault; 5.2, Inverse-infusion; 6, Abnormal door-opening; 7, Low battery power, battery fault; 8, Overtime pause; 9, Completed infusion; 10, AC power fault; 11, MCU fault, and stop infusion; 12, Battery temperature is too high. |
Data function | 1, Memory of calibration: Records the calibration data of tube automatically for application; 2, Memory of parameter: Records the latest feeding parameter for next operation; 3, Historical records: records latest 1000 feeding events. (what/when/why,flow-rate, etc.) |
Safety classification | Class I; Internal power supply, CF type, IPX4 equipment |
Power supply | AC 100~240V, 50/60Hz, Built-in rechargeable Li-battery |
Power consumption:20VA | |
Working time of battery: 7h@25ml/h | |
Weight and size | 130mm(w)*206mm(h)*118mm(t); about 1.6kg |
Optional accessories | 1, Warmer; 2, Wireless communicating module. |
Chinese Certificate | yes |
Packing
Product Size: 10.1*12.5*9CM
Package Size: 27*21*17CM
Net Weight: 1.2kg
Gross Weight: 1.7kg
Shipping:
Air shipping or Express courier is recommended if the order quantity was less than 20 units. It usually takes around 7 days to reach the destination. By ocean shipping, it normally takes 20-40 days depending on the destination port.