Product Details:
|
SIZE: | 12.1 Inch | Packing: | Cartoon Box |
---|---|---|---|
MOQ: | 1 | ||
Highlight: | Pathological Analysis Fetal Monitor,12.1 Inch Pathological Analysis Fetal Monitor,CCU Maternal Fetal Monitor |
12.1 Inch Hospital Medical ICU/CCU Cheap Price High Quality Pathological Analysis Fetal Monitor
Basic information:
Nine parameters | FHR, TOCO, FM, ECG,HR,SPO2,NIBP,RESP, TEMP |
Size | 12.1 inch portable maternal fetal monitor |
Weight | 3.55kg(with build-in two channel thermal printer) |
Voltage | 220v |
Power | 40w |
Leads | 3-5 leads |
Suitable places | hospital departments bedside care ward, ICU, CCU, operating theaters, prenatal care unit emergency centers, family care and the like. |
Optional | mobile stand/wall mount |
SFDA classification | Class II |
Working system |
Continuous running equipment
|
Features: |
1-7 level audio/visual alarming |
12" color TFT display, up to 12 waveforms |
3 in 1 transducers, no cable inter twisting. Arrhythmia analysis, ST calculation, Pace analysis |
Various interfaces: A single guide, standard, large font, all leads Anti-ESU, anti- defibrillator |
Patient info input management function |
Multi-lead ECG waveforms display in phase |
suitable for adults, children, newborns and unborn babies. |
new high-precision modules, new digital oxygen technology |
suitable for adults, children, newborns and unborn babies. |
Large volume of tabular and graphic trends information storage and easy to recall Built-in recorder and batter |
new high-precision modules, new digital oxygen technology
|
Standard configuration:
PM-9000E maternal fetal monitor×1 set,
build-in dual channel thermal printer×1 set,
triple fetal probe×1 set,
ultrasound gel×1 bottom,
probe bandages×1 set,
standard 5-leads ECG conductance joint connecting cables×1 set,
standard adult blood pressure cuffs×1 set,
adult SPO2 probe×1 set,
TEMP probe×1 set,
power plug line×1 set,
grounding wire×1 set,
English operation manual×1 set.
Three certificates×1 set.
Optional:
Build-in rechargeable lithium battery; monitor mobile stand/ cart.
Technical Parameters
FHR |
Probe: Nine wafer, wide beam, pulsed operation mode and high sensitivity. Ultrasound intensity: less than 1mW / cm² Operating frequency: 1.0MHz Signal Processing: dedicated digital signal processing unit Maximum Audio Output Power: 1.5W |
TOCO
|
10-100 pressure unit
|
|
Ultrasonic Probe Output
|
In accordance with the provisions of the international convention in 1992, IEC1157, negative peak sound pressure of not more than l trillion Pa (MPa). Beam sound intensity does not exceed 20 mW / cm 2 (mW / cm ²). Sound intensity spatial peak temporal average density of less than 100 mW / cm (mW / cm ²). The models sound intensity does not exceed 1mw / cm ² |
Coupling Agent (GEL)
|
Viscous water-based sets of objects. On the skin without stimulation, no allergies. Chemically stable, inhibit bacterial type.
|
|
ECG |
lead mode;I,II,III,AVR,AVL,AVF,V1-6 Gain: ×0.25, × 0. 5, and × 1, × 2 Frequency: 0.5 Hz - 100 Hz Common-mode signal inhibition: More than 70 dB Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls. HR: ± 5 BPM Precision calibration signal: 1mv(peak, ± 3% accuracy) ST Detection: measurement range (-2.0mV----+2.0mV) Using Standard: meet the ANSI / AMI EC13 -2002 standard Response time: 1s Alarm: Sound and Light Preset heart rate range: (Alarm over preset numerical) Ceiling: 1-255 bpm adjustable Threshold: 0-254 bpm adjustable |
NIBP |
Technology: Oscillography Mode: manual / automatic Measurement units: mmHg / kPa Scope: Pressure Cuffs 0-250 mmHg Inflatable cuffs: 180 mmHg (120mmHg for children, 70mmHg for newborn) Inflatable cuffs follow: original SBP: + 30 mmHg Measuring range: SYS: 60-250 mmHg DIA: 40-220 mmHg MEAN: 45-235 mmHg Response time: 1s Alarm: Sound and Light Preset range: report (Numerical exceed preset alarm) SYS: maximum: 1-255 mmHg adjustable Threshold: 0-254 mmHg adjustable DIA: ceiling: 1 -255 mmHg adjustable Minimum standards: 0-254mmHg adjustable |
|
SPO2 |
Range: 0-100% Accuracy: 1% Resolution: 1% Pulse frequency: 20-250 times / min Response time: 1s Alarm: Sound and Light Preset range: (report Alarm over preset numerical) Ceiling: 1% - 100% adjustable Threshold: 0% - 99% adjustable |
TEMP |
Technology: thermostat temperature probe Measuring range: 20 ° C-45 ° C Temperature resolution: 0.1% Accuracy: ± 0.1 ° C Response Time: 1s Alarm: Sound and Light Preset range: report (numerical preset alarm over) Maximum: 20.1 ° C-45.5 ° C adjustable Threshold: 20 ° C-45.4 ° C Adjustable |
|
RESP |
Breathing frequency range: 0-60 bum Accuracy: ± 1rpm Response time: 1s Gains options: × 1, × 2, × 0.5, and × 0.25 four trenches Alarm: Sound and Light Alarm range: (numerical preset alarm over) Ceiling: 10-100 bpm adjustable Threshold: 0 -99 bpm adjustable |
Printer(Optional)
|
Specification: Dual channel thermal array data recorder Print mode: Real time or event triggered record waveform and text Accuracy: horizontal: 4oodpi vertical: 800dpi Annotation: Date/ time(24 hours) Optional wall bracket, mobile stand, visits backpack. |
|
System |
Screen:12.1 inches TFT screen of LCD Battery: sealed maintenance-free lithium battery Safety standard: lec601-1(GB9706.1) |