Send Message
Home ProductsMaternal Fetal Monitor

9 Parameter Fetal Monitoring Device 12.1Inch 3-5 Leads Mobile Stand

Certification
China Hunan Province Rainbow Technology Co., Ltd. certification
China Hunan Province Rainbow Technology Co., Ltd. certification
I'm Online Chat Now

9 Parameter Fetal Monitoring Device 12.1Inch 3-5 Leads Mobile Stand

9 Parameter Fetal Monitoring Device 12.1Inch 3-5 Leads Mobile Stand
9 Parameter Fetal Monitoring Device 12.1Inch 3-5 Leads Mobile Stand 9 Parameter Fetal Monitoring Device 12.1Inch 3-5 Leads Mobile Stand 9 Parameter Fetal Monitoring Device 12.1Inch 3-5 Leads Mobile Stand 9 Parameter Fetal Monitoring Device 12.1Inch 3-5 Leads Mobile Stand 9 Parameter Fetal Monitoring Device 12.1Inch 3-5 Leads Mobile Stand 9 Parameter Fetal Monitoring Device 12.1Inch 3-5 Leads Mobile Stand

Large Image :  9 Parameter Fetal Monitoring Device 12.1Inch 3-5 Leads Mobile Stand

Product Details:
Place of Origin: Hunan,China
Brand Name: RAINBOW
Certification: ISO13485,FSC
Model Number: PM-9000E
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: USD 725-867
Packaging Details: carton box
Delivery Time: Within 3 days
Payment Terms: L/C, T/T, Western Union, MoneyGram
Supply Ability: 10000UNITS/YEAR

9 Parameter Fetal Monitoring Device 12.1Inch 3-5 Leads Mobile Stand

Description
Size: 12.1 Inch Brand Name: RAINBOW
Product Name: Fetal Monitor MOQ: 1
Highlight:

FSC Fetal Monitoring Device

,

12.1Inch Fetal Monitoring Device

China Reliable Factory High Quality Cheap Price 12.1 Inch 9 Parameters Fetal Monitor

Basic information:

Nine parameters FHR, TOCO, FM, ECG,HR,SPO2,NIBP,RESP, TEMP
Size 12.1 inch portable maternal fetal monitor
Weight 3.55kg(with build-in two channel thermal printer)
Voltage 220v
Power 40w
Leads 3-5 leads
Suitable places hospital departments bedside care ward, ICU, CCU, operating theaters, prenatal care unit emergency centers, family care and the like.
Optional mobile stand/wall mount
SFDA classification Class II
Working system Continuous running equipment

 

9 Parameter Fetal Monitoring Device 12.1Inch 3-5 Leads Mobile Stand 0

Features:
1.12" color TFT display, up to 12 waveforms
2.new high-precision modules, new digital oxygen technology
3.Arrhythmia analysis, ST calculation, Pace analysis
4.3 in 1 transducers, no cable inter twisting.
5.Anti-ESU, anti- defibrillator
6.Various interfaces: A single guide, standard, large font, all leads
7.Multi-lead ECG waveforms display in phase
8.Patient info input management function

 


9 Parameter Fetal Monitoring Device 12.1Inch 3-5 Leads Mobile Stand 1

Standard configuration:

PM-9000E maternal fetal monitor×1 set,

build-in dual channel thermal printer×1 set,

triple fetal probe×1 set,

ultrasound gel×1 bottom,

probe bandages×1 set,

standard 5-leads ECG conductance joint connecting cables×1 set,

standard adult blood pressure cuffs×1 set,

adult SPO2 probe×1 set,

TEMP probe×1 set,

power plug line×1 set,

grounding wire×1 set,

English operation manual×1 set.

Three certificates×1 set.

Optional:

Build-in rechargeable lithium battery; monitor mobile stand/ cart.

 

Technical Parameters

FHR

Probe: Nine wafer, wide beam, pulsed operation mode and high sensitivity.

Ultrasound intensity: less than 1mW / cm²

Operating frequency: 1.0MHz

Signal Processing: dedicated digital signal processing unit

Maximum Audio Output Power: 1.5W

TOCO

 

10-100 pressure unit

 

Ultrasonic Probe Output

 

In accordance with the provisions of the international convention in 1992, IEC1157, negative peak sound pressure of not more than l trillion Pa (MPa). Beam sound intensity does not exceed 20 mW / cm 2 (mW / cm ²). Sound intensity spatial peak temporal average density of less than 100 mW / cm (mW / cm ²). The models sound intensity does not exceed 1mw / cm ²

Coupling Agent (GEL)

 

Viscous water-based sets of objects. On the skin without stimulation, no allergies. Chemically stable, inhibit bacterial type.

 

ECG

lead mode;I,II,III,AVR,AVL,AVF,V1-6

Gain: ×0.25, × 0. 5, and × 1, × 2

Frequency: 0.5 Hz - 100 Hz

Common-mode signal inhibition: More than 70 dB

Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls.

HR: ± 5 BPM

Precision calibration signal: 1mv(peak, ± 3% accuracy)

ST Detection: measurement range (-2.0mV----+2.0mV)

Using Standard: meet the ANSI / AMI EC13 -2002 standard

Response time: 1s

Alarm: Sound and Light

Preset heart rate range: (Alarm over preset numerical)

Ceiling: 1-255 bpm adjustable

Threshold: 0-254 bpm adjustable

NIBP

Technology: Oscillography

Mode: manual / automatic

Measurement units: mmHg / kPa

Scope: Pressure Cuffs 0-250 mmHg

Inflatable cuffs: 180 mmHg (120mmHg for children, 70mmHg for newborn)

Inflatable cuffs follow: original SBP: + 30 mmHg

Measuring range: SYS: 60-250 mmHg

DIA: 40-220 mmHg

MEAN: 45-235 mmHg

Response time: 1s

Alarm: Sound and Light

Preset range: report (Numerical exceed preset alarm)

SYS: maximum: 1-255 mmHg adjustable

Threshold: 0-254 mmHg adjustable

DIA: ceiling: 1 -255 mmHg adjustable

Minimum standards: 0-254mmHg adjustable

SPO2

Range: 0-100%

Accuracy: 1%

Resolution: 1%

Pulse frequency: 20-250 times / min

Response time: 1s

Alarm: Sound and Light

Preset range: (report Alarm over preset numerical)

Ceiling: 1% - 100% adjustable

Threshold: 0% - 99% adjustable

TEMP

Technology: thermostat temperature probe

Measuring range: 20 ° C-45 ° C

Temperature resolution: 0.1%

Accuracy: ± 0.1 ° C

Response Time: 1s

Alarm: Sound and Light

Preset range: report (numerical preset alarm over)

Maximum: 20.1 ° C-45.5 ° C adjustable

Threshold: 20 ° C-45.4 ° C Adjustable

RESP

Breathing frequency range: 0-60 bum

Accuracy: ± 1rpm

Response time: 1s

Gains options: × 1, × 2, × 0.5, and × 0.25 four trenches

Alarm: Sound and Light

Alarm range: (numerical preset alarm over)

Ceiling: 10-100 bpm adjustable

Threshold: 0 -99 bpm adjustable

Printer(Optional)

 

Specification: Dual channel thermal array data recorder

Print mode: Real time or event triggered record waveform and text

Accuracy: horizontal: 4oodpi vertical: 800dpi

Annotation: Date/ time(24 hours)

Optional wall bracket, mobile stand, visits backpack.

System

Screen:12.1 inches TFT screen of LCD

Battery: sealed maintenance-free lithium battery

Safety standard: lec601-1(GB9706.1)

 

ECG

lead mode;I,II,III,AVR,AVL,AVF,V1-6

Gain: ×0.25, × 0. 5, and × 1, × 2

Frequency: 0.5 Hz - 100 Hz

Common-mode signal inhibition: More than 70 dB

Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls.

HR: ± 5 BPM

Precision calibration signal: 1mv(peak, ± 3% accuracy)

ST Detection: measurement range (-2.0mV----+2.0mV)

Using Standard: meet the ANSI / AMI EC13 -2002 standard

Response time: 1s

Alarm: Sound and Light

Preset heart rate range: (Alarm over preset numerical)

Ceiling: 1-255 bpm adjustable

Threshold: 0-254 bpm adjustable

NIBP

Technology: Oscillography

Mode: manual / automatic

Measurement units: mmHg / kPa

Scope: Pressure Cuffs 0-250 mmHg

Inflatable cuffs: 180 mmHg (120mmHg for children, 70mmHg for newborn)

Inflatable cuffs follow: original SBP: + 30 mmHg

Measuring range: SYS: 60-250 mmHg

DIA: 40-220 mmHg

MEAN: 45-235 mmHg

Response time: 1s

Alarm: Sound and Light

Preset range: report (Numerical exceed preset alarm)

SYS: maximum: 1-255 mmHg adjustable

Threshold: 0-254 mmHg adjustable

DIA: ceiling: 1 -255 mmHg adjustable

Minimum standards: 0-254mmHg adjustable

SPO2

Range: 0-100%

Accuracy: 1%

Resolution: 1%

Pulse frequency: 20-250 times / min

Response time: 1s

Alarm: Sound and Light

Preset range: (report Alarm over preset numerical)

Ceiling: 1% - 100% adjustable

Threshold: 0% - 99% adjustable

TEMP

Technology: thermostat temperature probe

Measuring range: 20 ° C-45 ° C

Temperature resolution: 0.1%

Accuracy: ± 0.1 ° C

Response Time: 1s

Alarm: Sound and Light

Preset range: report (numerical preset alarm over)

Maximum: 20.1 ° C-45.5 ° C adjustable

Threshold: 20 ° C-45.4 ° C Adjustable

RESP

Breathing frequency range: 0-60 bum

Accuracy: ± 1rpm

Response time: 1s

Gains options: × 1, × 2, × 0.5, and × 0.25 four trenches

Alarm: Sound and Light

Alarm range: (numerical preset alarm over)

Ceiling: 10-100 bpm adjustable

Threshold: 0 -99 bpm adjustable

Printer(Optional)

 

Specification: Dual channel thermal array data recorder

Print mode: Real time or event triggered record waveform and text

Accuracy: horizontal: 4oodpi vertical: 800dpi

Annotation: Date/ time(24 hours)

Optional wall bracket, mobile stand, visits backpack.

System

Screen:12.1 inches TFT screen of LCD

Battery: sealed maintenance-free lithium battery

Safety standard: lec601-1(GB9706.1)

 

9 Parameter Fetal Monitoring Device 12.1Inch 3-5 Leads Mobile Stand 29 Parameter Fetal Monitoring Device 12.1Inch 3-5 Leads Mobile Stand 3

 