Product Details:
|
Nine Parameters: | FHR, TOCO, FM, ECG,HR,SPO2,NIBP,RESP, TEMP | Size: | 12.1 Inch Portable Maternal Fetal Monitor |
---|---|---|---|
Weight: | 3.55kg(with Build-in Two Channel Thermal Printer) | Voltage: | 220v |
Power: | 40w | Leads: | 3-5 Leads |
Suitable Places: | Hospital Departments Bedside Care Ward, ICU, CCU, Operating Theaters, Prenatal Care Unit Emergency Centers, Family Care And The Like. | Optional: | Mobile Stand/wall Mount |
Highlight: | Multi Parameter Maternal Fetal Monitor,Fetus Maternal Fetal Monitor |
Basic information:
Nine parameters | FHR, TOCO, FM, ECG,HR,SPO2,NIBP,RESP, TEMP |
Size | 12.1 inch portable maternal fetal monitor |
Weight | 3.55kg(with build-in two channel thermal printer) |
Voltage | 220v |
Power | 40w |
Leads | 3-5 leads |
Suitable places | hospital departments bedside care ward, ICU, CCU, operating theaters, prenatal care unit emergency centers, family care and the like. |
Optional | mobile stand/wall mount |
SFDA classification | Class II |
Working system | Continuous running equipment |
Features:
new high-precision modules, new digital oxygen technology
12" color TFT display, up to 12 waveforms
3 in 1 transducers, no cable inter twisting.
Arrhythmia analysis, ST calculation, Pace analysis
Various interfaces: A single guide, standard, large font, all leads
Anti-ESU, anti- defibrillator
Patient info input management function
Multi-lead ECG waveforms display in phase
1-7 level audio/visual alarming
Large volume of tabular and graphic trends information storage and easy to recall
Built-in recorder and battery
suitable for adults, children, newborns and unborn babies.
Standard configuration:
PM-9000E maternal fetal monitor×1 set,
build-in dual channel thermal printer×1 set,
triple fetal probe×1 set,
ultrasound gel×1 bottom,
probe bandages×1 set,
standard 5-leads ECG conductance joint connecting cables×1 set,
standard adult blood pressure cuffs×1 set,
adult SPO2 probe×1 set,
TEMP probe×1 set,
power plug line×1 set,
grounding wire×1 set,
English operation manual×1 set.
Three certificates×1 set.
Optional:
Build-in rechargeable lithium battery; monitor mobile stand/ cart.
Technical Parameters
FHR |
Probe: Nine wafer, wide beam, pulsed operation mode and high sensitivity. Ultrasound intensity: less than 1mW / cm² Operating frequency: 1.0MHz Signal Processing: dedicated digital signal processing unit Maximum Audio Output Power: 1.5W |
TOCO
|
10-100 pressure unit
|
|
Ultrasonic Probe Output
|
In accordance with the provisions of the international convention in 1992, IEC1157, negative peak sound pressure of not more than l trillion Pa (MPa). Beam sound intensity does not exceed 20 mW / cm 2 (mW / cm ²). Sound intensity spatial peak temporal average density of less than 100 mW / cm (mW / cm ²). The models sound intensity does not exceed 1mw / cm ² |
Coupling Agent (GEL)
|
Viscous water-based sets of objects. On the skin without stimulation, no allergies. Chemically stable, inhibit bacterial type.
|
|
ECG |
lead mode;I,II,III,AVR,AVL,AVF,V1-6 Gain: ×0.25, × 0. 5, and × 1, × 2 Frequency: 0.5 Hz - 100 Hz Common-mode signal inhibition: More than 70 dB Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls. HR: ± 5 BPM Precision calibration signal: 1mv(peak, ± 3% accuracy) ST Detection: measurement range (-2.0mV----+2.0mV) Using Standard: meet the ANSI / AMI EC13 -2002 standard Response time: 1s Alarm: Sound and Light Preset heart rate range: (Alarm over preset numerical) Ceiling: 1-255 bpm adjustable Threshold: 0-254 bpm adjustable |
NIBP |
Technology: Oscillography Mode: manual / automatic Measurement units: mmHg / kPa Scope: Pressure Cuffs 0-250 mmHg Inflatable cuffs: 180 mmHg (120mmHg for children, 70mmHg for newborn) Inflatable cuffs follow: original SBP: + 30 mmHg Measuring range: SYS: 60-250 mmHg DIA: 40-220 mmHg MEAN: 45-235 mmHg Response time: 1s Alarm: Sound and Light Preset range: report (Numerical exceed preset alarm) SYS: maximum: 1-255 mmHg adjustable Threshold: 0-254 mmHg adjustable DIA: ceiling: 1 -255 mmHg adjustable Minimum standards: 0-254mmHg adjustable |
|
SPO2 |
Range: 0-100% Accuracy: 1% Resolution: 1% Pulse frequency: 20-250 times / min Response time: 1s Alarm: Sound and Light Preset range: (report Alarm over preset numerical) Ceiling: 1% - 100% adjustable Threshold: 0% - 99% adjustable |
TEMP |
Technology: thermostat temperature probe Measuring range: 20 ° C-45 ° C Temperature resolution: 0.1% Accuracy: ± 0.1 ° C Response Time: 1s Alarm: Sound and Light Preset range: report (numerical preset alarm over) Maximum: 20.1 ° C-45.5 ° C adjustable Threshold: 20 ° C-45.4 ° C Adjustable |
|
RESP |
Breathing frequency range: 0-60 bum Accuracy: ± 1rpm Response time: 1s Gains options: × 1, × 2, × 0.5, and × 0.25 four trenches Alarm: Sound and Light Alarm range: (numerical preset alarm over) Ceiling: 10-100 bpm adjustable Threshold: 0 -99 bpm adjustable |
Printer(Optional)
|
Specification: Dual channel thermal array data recorder Print mode: Real time or event triggered record waveform and text Accuracy: horizontal: 4oodpi vertical: 800dpi Annotation: Date/ time(24 hours) Optional wall bracket, mobile stand, visits backpack. |
|
System |
Screen:12.1 inches TFT screen of LCD Battery: sealed maintenance-free lithium battery Safety standard: lec601-1(GB9706.1) |
|||
ECG |
lead mode;I,II,III,AVR,AVL,AVF,V1-6 Gain: ×0.25, × 0. 5, and × 1, × 2 Frequency: 0.5 Hz - 100 Hz Common-mode signal inhibition: More than 70 dB Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls. HR: ± 5 BPM Precision calibration signal: 1mv(peak, ± 3% accuracy) ST Detection: measurement range (-2.0mV----+2.0mV) Using Standard: meet the ANSI / AMI EC13 -2002 standard Response time: 1s Alarm: Sound and Light Preset heart rate range: (Alarm over preset numerical) Ceiling: 1-255 bpm adjustable Threshold: 0-254 bpm adjustable |
NIBP |
Technology: Oscillography Mode: manual / automatic Measurement units: mmHg / kPa Scope: Pressure Cuffs 0-250 mmHg Inflatable cuffs: 180 mmHg (120mmHg for children, 70mmHg for newborn) Inflatable cuffs follow: original SBP: + 30 mmHg Measuring range: SYS: 60-250 mmHg DIA: 40-220 mmHg MEAN: 45-235 mmHg Response time: 1s Alarm: Sound and Light Preset range: report (Numerical exceed preset alarm) SYS: maximum: 1-255 mmHg adjustable Threshold: 0-254 mmHg adjustable DIA: ceiling: 1 -255 mmHg adjustable Minimum standards: 0-254mmHg adjustable |
SPO2 |
Range: 0-100% Accuracy: 1% Resolution: 1% Pulse frequency: 20-250 times / min Response time: 1s Alarm: Sound and Light Preset range: (report Alarm over preset numerical) Ceiling: 1% - 100% adjustable Threshold: 0% - 99% adjustable |
TEMP |
Technology: thermostat temperature probe Measuring range: 20 ° C-45 ° C Temperature resolution: 0.1% Accuracy: ± 0.1 ° C Response Time: 1s Alarm: Sound and Light Preset range: report (numerical preset alarm over) Maximum: 20.1 ° C-45.5 ° C adjustable Threshold: 20 ° C-45.4 ° C Adjustable |
RESP |
Breathing frequency range: 0-60 bum Accuracy: ± 1rpm Response time: 1s Gains options: × 1, × 2, × 0.5, and × 0.25 four trenches Alarm: Sound and Light Alarm range: (numerical preset alarm over) Ceiling: 10-100 bpm adjustable Threshold: 0 -99 bpm adjustable |
Printer(Optional)
|
Specification: Dual channel thermal array data recorder Print mode: Real time or event triggered record waveform and text Accuracy: horizontal: 4oodpi vertical: 800dpi Annotation: Date/ time(24 hours) Optional wall bracket, mobile stand, visits backpack. |
System |
Screen:12.1 inches TFT screen of LCD Battery: sealed maintenance-free lithium battery Safety standard: lec601-1(GB9706.1) |
Packing
Packing terms: Anti-collision film+ Carton box
Carton box dimension: 40*30*35cm
Gross weight: 6.30kg
Shipping:
Air shipping or Express courier is recommended if the order quantity was less than 20 units. It usually takes around 7 days to reach the destination. By ocean shipping, it normally takes 20-40 days depending on the destination port.
What is your MOQ?
1 unit
What is your lead time?
Within 3 days after receiving the payment
What is the payment terms?
TT(Bank Transfer), Paypal, Western Union, Moneygram, XTransfer.
What is the warranty period?
2 years warranty period
Lifetime online technical support
Do you offer OEM service?
Yes, we do
Contact Person: Lily